Part Number Hot Search : 
ATS03 CLE131 4556B 2SK824 1017A 200AA 2SK15 6158M0
Product Description
Full Text Search
 

To Download TLP150 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Embedded Power for Business-Critical Continuity
TLP150 Series
Single output
Rev.1.08.09_146 TLP150 1 of 4
Total Power: 150W Input Voltage: 85 - 264VAC # of Outputs: Single
RoHS
Special Features
* * * * * * * * * * * * 150Wonmainchannel withonly200LFM Lowprofilefits1Uapplications ActivePFCand EN61000-3-2compliant IntegratedOr-ingdiode Activecurrentsharing Integratedcontroland monitoring features Overcurrent,overvoltageand overtemperatureprotection CompliancetoEN55022-B conducted noise standard 12Vfanoutput 5Vstandbyoutput(optional) RoHScompliant 2yearwarranty
ElectricalSpecifications
Output
Adjustmentrange: Totalregulation: (lineandload) Turn-on delay Transient response Mainoutput Auxiliaryoutputs Fan output @120Vacinput Mainoutput 25%to75% stepat0.5A/s Mainoutputs Current limited Singles SeeNote9 SeeNote9 Universalinput 264Vac(coldstart) 264Vac,50Hz 120Vac@250W 230Vac@250W UL/iEC127 5% 3% 5% 10% 2.0smax. 5% max.dev.,1msmax. recoveryto1% 0.02%/C 125%5% Continuous 0A 12V@0.5A 5V@1.0A 85-264Vac 47-63Hz 40Amax. 1mA 1.8Arms 0.8Arms T3.15A,250Vac
Temperaturecoefficient Overvoltageprotection Shortcircuitprotection Minimumoutputcurrent Fanvoltageoutput Standby output
Input
Inputvoltagerange:
Safety
* VDEEN60950-1/IEC60950-1 * UL60950-1/CSA22.2 No.60950-1
Inputfrequencyrange: Inputsurgecurrent: Safetygroundleakagecurrent: Inputcurrent: Inputfuse:
Embedded Power for Business-Critical Continuity
EMCCharacteristics
Conductedemissions: harmoniccurrentcorrection: ESDair: ESDcontact: Fasttransients: Surge: Conductedimmunity: EN55022,FCCpart15 EN61000-3-2 EN61000-4-2 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-6 85Vac@60Hz 115Vac@150W 230Vac@150W Input/output Input/chassis LevelB Compliant Level3 Level3 Level3 Level3 Level3 20ms@150W 81%typ. 84%typ. 3000Vac 1500Vac
Rev.1.08.09_146 TLP150 of 4
GeneralSpecifications
Hold-uptime: Efficiency: Isolationvoltage: Safetyapprovals: (seenote6) Weight: MTBF(@25C)
UL/cULUL60950-1/CSA22.2No.60950-1 VDEEN60950-1/IEC60950-1 260g(9.2oz) TelcordiaSR-332 MIL-HDBK-217F 900,000hoursmin. 350,000hoursmin.
EnvironmentalSpecifications
Thermalperformance: Operatingambient, (Seederatingcurve) Non-operating 0Cto50Cambient, 200LFMforcedair 0Cto50Cambient, convectioncooled 50Cto70Cambient, Relativehumidity: Altitude: Vibration(SeeNote7): Shock: Non-condensing Operating Non-operating 5-500Hz perMIL-STD-810E 0Cto+70C -40Cto+85C 150W 100W Deratelinearlyto50%load 5-95%RH 10,000feetmax. 30,000feetmax. 2.4Grmspeak 516.4PartIV
Embedded Power for Business-Critical Continuity
OrderingInformation
Output Voltage 12V 24V 36V 48V Notes Output Currents Min 0A 0A 0A 0A Max (free air)(1, 4) Max (force air) (2,4) 8.4A 4.2A 2.7A 2.1A 12.5A 6.3A 4.2A 3.2A 120mV 240mV 360mV 480mV Ripple (3) Total Regulation 3.0% 3.0% 3.0% 3.0% Moel uers (9, 10) oel
Rev.1.08.09_146 TLP150 of 4
TLP150R-96S12J TLP150R-96S24J TLP150R-96S36J TLP150R-96S48J
1 Freeairconvection.Maximumcontinuousoutputpowernottoexceed100 W. RefertoFigure1forthederatingcurve. 2 200LFMforcedaircoolingfromtheacinputside.Maximumcontinuousoutput powernottoexceed150W. 3 Figureispeak-to-peakforroomtemperaturerating.Outputnoisemeasurements aremadeacrossa20MHzbandwidthusinga6inchtwistedpair,terminatedwith a10Ftantalumcapacitoranda0.1Fceramiccapacitor. 4 CAUTION:Allowaminimumof1secondafterdisconnectinglinepowerwhen makingthermalmeasurements.Foroptimumreliabilitynopartoftheheatsink shouldexceed115Candnosemi-conductorcasetemperatureshouldexceed 120C. 5 Noexternalfilteringrequiredduringconductedemissionstestingbutsome applicationsmayrequireadditionalfilteringtoachievesystemcompliance. CompliancewithradiatedEMIspecificationsmayrequiremountinginasuitable enclosure. 6 Thisproductisonlyforinclusionbyprofessionalinstallerswithinotherequipment andmustnotbeoperatedasastandaloneproduct. 7 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4G 8 Replacethe`J'attheendofthemodelnumberwith`FJ'whentheoptional standbyoutputand/orremoteON/OFFcontrolisrequired e.g.TLP150R-96S12FJ. 9 12V(fan)presentwhenmainoutputispresent.Anoptional5Vsb(standby) outputisavailablewheneveracinputispresent,regardlessofremoteON/OFF signalstatus. 10 The`J'suffixindicatesthatthesepartsarePb-free(RoHS6/6)compliant.The`Y' suffixindicatesTSERoHS5/6(nonPb-free)compliantversionsmaybeavailable onspecialrequest,pleasecontactyourlocalsalesrepresentativefordetails. 11 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal EmersonNetworkPowerrepresentativeorusetheon-linemodelnumbersearch toolathttp://www.PowerConversion.com. 12 Powergoodsignalrequired100mAloadonthemainoutput(checkwith engineeringonallmodels).
DERATING CURVE Output Power (Watts) 150 W 200 LFM (1.0 m/s) FORCED AIR COOLING 100 W 75 W NATURAL CONVECTION COOLING
50 W
0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
Figure1:DeratingCurve
Outline Dimensions
5.000 (127.00) 4.550 (115.57)
J3 3.000 (76.20) 2.550 (64.77)
J1 1
Neutral Live J2
FAN
1 J4 1
0.225 (5.72)
1
R88 Ground/Earth 0.225 (5.72)
Trimmer Adjust Output Voltage
1
J301
Total Height 1.250 (31.75)
o0.156 (4 Places)
Dimensions in Inches (mm)
Figure2:MechanicalDrawing
Embedded Power for Business-Critical Continuity
ConnectorandMatingConnectorTypes
Connector
J1 J2 J3 J4
Type
Molex09-65-2038(5273series) voidpin2orequivalent AMP63849-1orequivalent (6.35mmstraight) Molex09-65-2068(5273series) orequivalent Molex22-23-2061(6373series) orequivalent
MatingConnectorType
Molex09-52-4034(5239series)orequivalentwith Molex08-52-0072(2478series)orequivalentcrimpterminals AMP2-520263-4orequivalent (straightspadefor22-18AWGwire) Molex09-52-4064(5239series)orequivalentwith Molex08-52-0072(2478series)orequivalentcrimpterminals Molex22-01-3067(2695series)orequivalentwith Molex08-50-0113(2759series)orequivalentcrimpterminals
Americas
5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698
Rev.1.08.09_146 TLP150 4 of 4
Europe(UK)
J301 (Optional)
Leoco2421P04H000(2421series) Leoco2420S04000(2420series)orequivalent orequivalent withLeoco2453TPH00V1(2453Tseries)orequivalentcrimpterminals or JSTEHR-4(EHseries)orequivalentwith JSTSEH-001T-P0.6(EHseries)orequivalentcrimpterminals Molex22-23-2021(6373series) orequivalent Molex22-01-3027(2695series)orequivalentwith Molex08-50-0113(2759series)orequivalentcrimpterminals
WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355
Asia(HK)
Fan
Pin Connections
J1PinConnections
Pin1 Pin2 Tab Neutral Live Pin1 Pin2 Pin3 Pin4 Pin5 Pin 6 Pin1 Pin2 Pin3 Pin4 Pin5 Pin 6 Pin1 Pin2 Pin3 Pin4 Pin1 Pin2
14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888
J3PinConnections
RTN RTN RTN Vo Vo Vo MainReturn MainReturn MainReturn +MainOutput +MainOutput +MainOutput -VoRemoteSense DCPowerGoodSignal PowerGood* LoadShareSignal +VoRemoteSense Signal Common StandbyVoltage Signal Common DoNotConnect RemoteON/OFFSignal FanVoltage Return
Forglobalcontact,visit:
www.PowerConversion.com techsupport.embeddedpower @emerson.com
Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis inforation or for any errors or oissions.
J2TabConnections
Ground/Earth
J4PinConnections
-S DCOK PWOK LS +S SGND 5Vsn SGND Reserved PSOFF +12V +SGND
EmersonNetworkPower. Thegloballeaderinenabling business-criticalcontinuity. ACPower Connectivity DCPower Embedded Computing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls Precision Cooling Racks&IntegratedCabinets Services Surge Protection EmersonNetworkPower.com
EmersonNetworkPowerandtheEmerson Network Power logo are trademarks and servicemarksofEmersonElectricCo. (c)2008EmersonElectricCo.
J301PinConnections(Optional)
Fan Pin Connections


▲Up To Search▲   

 
Price & Availability of TLP150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X